安科瑞多回路仪表在加纳数据中心的应用
浏览次数:552发布日期:2021-08-09

摘要:数据中心是一个聚集了大量服务器、存储设备、网络设备及配套UPS、空调等设备的IT设备场所,是实现数据信息的集中处理、存储、传输、交换和集中管理等业务的服务平台。

数据中心供电电源质量的好坏直接影响到IT设备的安全运行,因此对数据中心列头柜电源进出线实行监测非常重要,另外,随着全球可用能源的减少以及能源成本的提高,如何更加经济和使用能源已成为相关企业责无旁贷的责任

Abstract: Data  center is a place that gathering a large number of servers, storage  equipment, network equipment and supporting UPS, precision air  conditioning and other IT equipment, is to realize the centralized  processing, storage, transmission, exchange and centralized management  of data and information service platform.

Data  center power supply quality directly affects the safe operation of the  IT equipment, thus the data center column header tank outlet and inlet  line of power supply monitoring is very important, in addition, as the  global of available energy and reduced energy costs rise, how much more  economic and efficient use of energy has become a duty-bound  responsibility related enterprises.

1.项目概述 Project overview

针对数据中心列头柜对于监测装置的要求,我司设计了AMC16-FAK48数据中心监控装置来实现多路出线的电参数及进出线开关状态等实现监测。Maxitech是加纳的数据中心解决方案供应商,客户有两个柜子,分别有20个出线回路要进行监测,同时后期还有10-20个回路会增加,所以客户选择了AMC16Z-FAK,它可以同时监测48个出线回路,客户测量电流为100A,所以搭配使用我们的AKH-0.66W-12N互感器。

According  to the requirements of data center array cabinet for monitoring device,  our company designed AMC16-FAK48 data center monitoring device to  realize the electrical parameters of multiple outgoing lines and the  switch state of incoming and outgoing lines to achieve comprehensive  monitoring. Maxitech is the data center System solution provider in  Ghana. The customer has two cabinets with 20 outlet loops to be  monitored, and 10-20 loops will be added later, so the customer chooses  AMC16Z-FAK, which can monitor 48 outlet loops at the same time. The  customer's measured current is 100A, so our AKH-0.66W-12N transformer is  used together. 

2. 功能 Function

 

2.技术参数Technical Features

 

3.组网拓扑图 Network topology

  

4.现场图片Photo on-site

 

5.结束语Conclusion

随着数据中心的迅猛发展,数据中心的能耗问题也越来越突出,有关数据中心的能源管理和供配电设计已经成为热门问题,可靠的数据中心配电系统方案,是提高数据中心电能使用效率,降低设备能耗的方式。要实现数据中心的节能,首先需要对每个用电负载实现监测,而数据中心负载回路非常的多,传统的测量仪表无法满足成本、体积、安装、施工等多方面的要求,因此需要采用适用于数据中心集中监控要求的多回路监控装置。

而AMC16M是专门针对数据中心交流列头柜开发设计的,对此类产品的应用做了深入的研究,从功能、性能、可用性、经济性等方面都优于其他方案。

With  the rapid development of data centers, the problem of energy  consumption in data centers is becoming more and more prominent. Energy  management and power supply and distribution design of data centers have  become hot issues. Efficient and reliable data center power  distribution system scheme is an effective way to improve the power use  efficiency of data centers and reduce the energy consumption of  equipment.To realize the energy saving of the data center, you will  first need to achieve precise monitoring of each power load, the load  circuit and data center very much, the traditional measuring meters can  meet the cost, size, installation, construction and other aspects of  requirements, so you need to use applies to data center centralized  monitoring requirement of multi loop monitoring device.

The  AMC16M is specially designed for array cabinet in data center. The  application of this kind of product has been studied in depth, and it is  superior to other schemes in terms of function, performance,  availability and economy.